| Award |
 |
|
|
|
| |
|
 |
| Finger Tip |
| |
|
|
| |
| Standard Features |
| » |
Display format : 64K color OLED. |
| » |
Display Mode : Two Direction |
| » |
Back Light : OLED |
| » |
SpO2 : 35-99% |
| » |
Pulse Ratio : 30 – 255 BPM |
| » |
Pleth wave : OLED Graphic Display |
| » |
Battery voltage Low Indication : OLED Bar Graph. |
| » |
Power Requirements : Two AAA size 1.5 VA Alkaline Battery |
| » |
Power Consumption : less than 60 mA. |
| » |
Resolution : 1% for SpO2 and 1 BPM for Pulse Ratio. |
| » |
Measurement Accuracy : + 2% in stage of 70% - 99% for SpO2. |
| » |
Unspecified in stage of 35-69% for SpO2. |
| » |
± 2BPM or ± 2% (Select Larger) for Pulse Ratio. |
| » |
Measurement performance in low perfusion : SpO2 and Pulse Rate & # 118 value can be shown correctly when the pulse-filling ratio is 0.4%. |
| » |
Interference Resistance Capacity against ambient light : Deviation is smaller than ± 1%. |
| » |
It is equipped with a function switch, through which the oximeter can be automatically powered off when no finger is in the oximeter more than 4 seconds.
|
|
|
|
| |
| Hand Held |
| |
 |
| Standard Features |
| » |
High accuracy and reliable performance |
| » |
High resolution LCD with backlight |
| » |
Visual & Audio alarm |
| » |
Compact design for carrying and handling |
| » |
Low power consumption and up to 24 hours continuously operation |
| » |
72 hours record storage |
| » |
Rubber jacket providing additional protection |
| » |
4 AA alkaline or rechargeable batteries |
| » |
AC/DC adapter (optional) |
| » |
Multi-language version (optional) |
| » |
Intelligent background lighten design |
| » |
Suitable for adult, pediatric and neonatal |
|
|
|
| |
| Specification |
| Patient Range |
Adult, Pediatric and Neonatal |
| SpO2 |
| Range |
0% - 100% |
| Resolution |
1% |
| Accuracy |
70% - 100% : ± 2%
0% - 63% : unspecified |
| Method |
Dual wavelength LED |
| Heart (Pulse) Range |
| Range |
0 - 255 bpm |
| Resolution |
1 bpm |
| Accuracy |
±2 bpm or ±2% |
| Alarm |
| Alarm |
SpO2, PR, Probe off |
| Modes |
Audio, visual, information |
| Display |
| Type |
Backlight LCD |
| Parameters |
SpO2, PR, Pleth waveform, Pleth bar |
| Information |
SpO2 & PR trend, browse, Low power, error, time |
| Environmental |
| Operating Temperature |
0°C - 50°C |
| Storage temperature |
10°C - 60°C |
| Operating Humidity |
15% RH - 95% RH |
| Storage Humidity |
10% RH - 95% RH |
| Classification |
| Type of protection |
internally powered equipment |
| Safety |
IEC Standard 61601-1-1 |
| Storage |
| Data records |
up to 72 hours |
| Mechanical |
| Size |
150 X 94 X 47 mm |
| Weight |
440g (including batteries) |
| Power |
| Type |
4 AA Alkaline batteries or Rechargeable batteries or AC/DC adapter |
| Operation time |
Approximately 24 hours for normal operation |
|
|
| |
|
| |
|
| |
|
|
|